| Voltage | AC 90-264V |
| Respiration Rate Range | 0 ~ 1001rpm |
| Respiration Accuracy | 2 rpm |
| Screen Type | 8 Inch TFT |
| Resolution | 400dpi vertical, 800dpi horizontal |
| Brand | DRE |
Portable patient monitor with a user-friendly touch-screen — Now with Masimo SET® Pulse Oximetry!
ECG, Respiration, Masimo SpO2, Noninvasive Blood Pressure and Temperature. Available with a printer.
Featuring cutting-edge innovations and impeccable craftsmanship, the DRE Waveline EZ patient monitor is the perfect choice for healthcare professionals who demand precision, performance and affordability. It features an intuitive touchscreen that helps you quickly and accurately evaluate patient conditions, resulting in better patient care. Utilize the Waveline EZ to monitor ECG, respiration, SpO2, NIBP and temperature; it’s also available with EtCO2 monitoring and a printer.
Features:- Touch-screen provides immediate operation
- Simultaneous multi-lead ECG monitoring
- New for 2015! Masimo SET® Pulse Oximetry — ask your DRE representative for details
- Advanced ST and arrhythmia detection
- Graphical and tabular trending
- Displays three waveforms
- Battery backup
- Audible and visual alarms
- Quick BP readings recall
ECG:- Patient Safety Standard: IEC60601-1-1988
- CMRR ≥60dB (Common Mode Rejection Ratio)
- Heart Rate Range: 20 ~ 254bpm 1bpm
- Heart Rate Averaging: 8 second average
- ST Segment Range: -0.8 ~ + 0.8mV
- Interface: AAMI 6-pin
- Lead Selection: I, II, III (3 lead mode)
- I, II, III, aVR, aVL, aVF, V (5 lead mode) (ST and Arrhythmia analysis)
- Lead Fault Alarm: Audible, Visual Input 5-lead ECG patient cable
- QRS Indicator: Audible and Visual Alert
- Waveform Storage: 6 minutes
- Sweep Speed: 12.5/25/50 mm/sec
- Gain Selection:4mV, 2mV, 1mV, 0.5mV, 0.25mV,Auto
- Trends: 2 hours -> 4 hours -> 8 hours -> 24 hours -> 48 hours
- Patient Isolation Breakdown: voltage 4000VAC 50Hz 60 seconds Leakage current <10μA
- Frequency width Monitoring: mode 0.5 ~ 40Hz (+0.4dB,-3.0dB) Surgery mode 0.5 ~ 20Hz (+0.4dB, -3.0dB) not calibration significant
- Patient Drive Current: <10μA
- Enclosure Leakage Current: <0.1mA
- Maximum T Wave Rejection Capability: 1.2mV
- Heart Rate Alarm Response Time:< 7 seconds
- Aspect Ratio: 0.24 ~ 0.6 sec/mV
- Alarm Frequency Low alarm: 2-2.4kHz High alarm: 3-3.4kHz
- Defibrillator Protected & ESIS Protected Tested with 5kV
- Recovery Time Following Defibrillation: <5 seconds
RESP:- Measurement Method: Thoracic Impedance
- Respiration Rate Range: 0 ~ 1001rpm
- Accuracy: 2 rpm
NIBP:- Method Automatic oscillometric
- Parameters Systolic, diastolic, mean arterial pressure, pulse
- Scale mmHg or kPa
- Operating Modes Manual, Automatic, Continuous
- Repeat Cycles 1 ~ 10, 15, 30, 60, 90, 120 minutes
- Determination Systolic, Adult/pediatric 40 ~ 250mmHg (5.3 ~ 33.3kPa) Systolic, Neonate 20 ~ 160mmHg (2.7 ~ 21.3kPa) Diastolic, Adult/pediatric 10 ~ 180mmHg (1.3 ~ 24.0kPa) Diastolic, Neonate 10 ~ 140mmHg (1.3 ~ 18.7kPa)
- Cuff Pressure Range Adult/pediatric 0 ~ 300mmHg (0 ~ 40.0kPa) Neonate 0 ~ 140mmHg (0 ~ 18.7kPa)
- Initial Cuff Inflation Adult/pediatric 17010mmHg (22.7 1.3kPa) Neonate 10010mmHg (16.0 1.3kPa)
- Deflation Pressure 30mmHg(4.0kPa) higher than the last systolic pressure
- Cuff Inflation Rate No greater than 50mmHg/sec
- Measurement Time Typical 25 seconds, Maximum 40 seconds, Typical Stat 20 seconds
- Pressure Display Accuracy 3mmHg
- BP Pulse Rate Accuracy 2% @ 40 ~240bpm
- Cuff Neonate, infant, pediatric,standard adult